Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 107
Filter
1.
Indian Heart J ; 2023 Apr; 75(2): 133-138
Article | IMSEAR | ID: sea-220972

ABSTRACT

Context: Complex left atrial appendage (LAA) morphology is increasingly associated with cryptogenic ischemic stroke as compared to cardioembolic stroke due to atrial fibrillation (AF). However, data on such an association in patients with other etiological stroke subtypes in the absence of AF is limited. Aim: The study aimed to assess the LAA morphology, dimension and other echocardiographic parameters by transesophageal echocardiography (TEE) in patients with embolic stroke of undetermined source (ESUS) and compare it with other etiological stroke subtypes without known AF. Methods: This was a single-Centre, observational study involving comparison of echocardiographic parameters including LAA morphology and dimension in ESUS patients (group A; n ¼ 30) with other etiological stroke subtypes i.e., TOAST (Trial of Org 10172 in Acute Stroke Treatment) class I-IV without AF (group B; n ¼ 30). Results: Complex LAA morphology was predominant in group A (18 patients in group A versus 5 patients in group B, p-Value ¼ 0.001). Mean LAA orifice diameter (15.3 þ 3.5 mm in group A versus 17 þ 2.0 mm in group B, p-Value ¼ 0.027) and LAA depth were significantly lower in group A (28.4 þ 6.6 mm in group A versus 31.7 þ 4.3 mm in group B, p-Value ¼ 0.026). Out of these three parameters only complex LAA morphology was found to be independently associated with ESUS [OR ¼ 6.003, 95% CI {1.225e29.417}, p ¼ 0.027]. Conclusion: Complex LAA morphology is a predominant feature in ischemic stroke patients with ESUS and may contribute to an increased risk of stroke in these patients.

2.
Chinese Journal of Postgraduates of Medicine ; (36): 14-18, 2023.
Article in Chinese | WPRIM | ID: wpr-990959

ABSTRACT

Objective:To assess the safety and efficiency of left atrial appendage closure (LAAC) combined delayed anticoagulant therapy in atrial fibrillation (AF) patients combined with cardiogenic stroke during anticoagulant therapy.Methods:Using prospective research methods, 35 AF patients combined with cardiogenic stroke during anticoagulant therapy from September 2020 to June 2022 in Xuanwu Hospital, Capital Medical University were selected. All patients were treated with LAAC and delayed anticoagulant therapy. The endpoints were the safety and efficacy of LAAC combined with delayed anticoagulant therapy. The primary endpoint of efficacy was the composite endpoint of postoperative death, myocardial infarction, hemorrhagic stroke and systemic embolism. The safety endpoint was major bleeding as defined by the International Society for Thrombosis and Hemostasis and clinically relevant non-major bleeding.Results:Among 35 patients, 21 were males and 14 were females; the age was (68.5 ± 9.3) years old; the CHA 2DS 2-VASc score was 5 (4, 6) scores; the time to the last stroke was 95 (42, 98) d; the National Institutes of Health stroke scale score at the time of stroke was 3 (1, 6) scores. All patients successfully completed LAAC without perioperative instrument-surface thrombosis, death, new stroke or bleeding events. Thirty-two patients continued oral anticoagulant therapy 45 d after LAAC. The patients were followed up for (12.6 ± 4.3) months, 1 patient experienced recurrent ischemic stroke, 2 patients endured mucosal bleeding, there were no adverse events such as all-cause death, cardiovascular death, systemic embolism and hemorrhagic stroke. Conclusions:The LAAC combined delayed anticoagulant therapy is efficient and safe in patients with AF. For AF patients combined with cardiogenic stroke during anticoagulant therapy, LAAC combined with delayed anticoagulation therapy may be considered to further prevent ischemic stroke events.

3.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 784-786, 2023.
Article in Chinese | WPRIM | ID: wpr-996618

ABSTRACT

@#Surgical treatment of atrial septal defect (ASD) mainly includes occlusion or repair under cardiopulmonary bypass. Surgical treatment of atrial fibrillation includes transcatheter radiofrequency ablation or Maze surgery under cardiopulmonary bypass. There are many treatments for ASD patients combined with atrial fibrillation, but each has its own advantages and disadvantages. We reported an ASD patient combined with atrial fibrillation treated by totally endoscopic "one-stop" radiofrequency ablation and simultaneous transthoracic ASD occlusion of atrial fibrillation, with good postoperative results.

4.
Ann Card Anaesth ; 2022 Sep; 25(3): 366-367
Article | IMSEAR | ID: sea-219242

ABSTRACT

A 4?year?old child with supramitralmembrane (SMM) causing severemitral stenosis (MS) was taken for excision of themembrane. Intraoperative transesophageal echocardiography showed a large thrombus in the left atrial appendage (LAA) in addition to SMM.The case underscores the importance of this extremely rare association and prompt therapy to prevent catastrophic consequences.

5.
Article | IMSEAR | ID: sea-219974

ABSTRACT

Background: Mitral stenosis (MS) is a common valvular heart disease. Thromboembolism is one of the most serious consequences of mitral stenosis, particularly when it is accompanied with atrial fibrillation (AF). When linked with Left atrial appendage inactivity (LAAI), patients with sinus rhythm (SR) are also at risk for this condition. In mitral stenosis, LAA inactivity determined by S-wave is an independent predictor of thromboembolism. The aim of the study was to evaluate the Prevalence and Echocardiographic Predictors of Left Atrial Appendage inactivity in patients of Mitral Stenosis.Material & Methods:Sixty MS patients were evaluated by transthoracic echocardiography (TTE) and all patients underwent transesophageal echocardiography (TEE). The annular systolic (S-wave) and diastolic (Em- and Am-waves) velocities were recorded by tissue Doppler imaging (TDI). LAA inactivity was defined as LAA emptying velocity <25 cm/second determined by pulse wave Doppler at the junction of LA & LAA (TEE). Patients were divided into three groups; group A I (n = 18). Sinus rhythm (SR) and LAA emptying velocity ?25 cm/sec, group A II (n -22): SR and LAA emptying velocity <25cm/sec and group B (n = 20): atrial fibrillation.Results:Thrombus was detected in 14 patients and spontaneous echo contrast (SEC) was detected in 43 patients. Both S-wave and peak LAA emptying velocities were decreasing, while SEC frequency and density were increasing from group A to group B. There was a positive correlation between LAA emptying vs. S-wave and LAA emptying vs. Am velocities (p < 0.001, r= 0.708 and p<0.001, r=0.495). Multivariate regression analysis showed that only S-wave is the independent predictor of inactive LAA (p = 0.001, odds ratio = 0.133, 95% Cl =0.032-0.556). In patients with SR, the cutoff value of S-wave was 10 cm/sec for the prediction of the presence of inactive LAA (sensitivity: 92.3%, specificity: 95.3%).Conclusions:In individuals with severe mitral stenosis in sinus rhythm, there is a significant prevalence of left atrial appendage inactivity. The mean pressure gradient across the mitral valve, as well as S-wave are independent predictors of left atrial appendage inactivity. Inactivity of the left atrial appendage is an independent predictor of left atrial/left atrial appendage smoke and associated thrombus.

6.
Rev. colomb. cardiol ; 29(2): 244-247, ene.-abr. 2022. graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1376886

ABSTRACT

Resumen La fibrilación auricular es la arritmia más prevalente en la práctica clínica, y se asocia con una morbimortalidad significativa, la cual, en parte, se explica por el riesgo de fenómenos embólicos. En la actualidad, el uso de anticoagulantes es el estándar de manejo en aquellos pacientes con riesgo embólico significativo (dado por un puntaje ≥ 2 en la escala CHA2DS2Vasc). Sin embargo, algunos pacientes tienen contraindicaciones que impiden recibir este tipo de tratamiento a largo plazo, en cuyo caso se considera el cierre percutáneo de la orejuela como medida para la disminución del riesgo de embolia. Al requerir una punción transeptal, la presencia de dispositivos de cierre de defectos del septo interauricular dificulta el procedimiento de manera significativa. Se presenta el caso de una paciente con contraindicación absoluta para recibir anticoagulantes debido a sangrado gastrointestinal y antecedente de cierre percutáneo de comunicación interauricular sometida a cierre percutáneo de orejuela como alternativa terapéutica a la anticoagulación.


Abstract Atrial fibrillation is the most prevalent arrythmia in clinical practice, associated with a significant morbimortality explained, in part, by the high risk of embolic phenomena. The use of anticoagulation is the standard of care in those patients with increased embolic risk (given by a score ≥ 2 in the CHA2DS2Vasc scale). However, some patients have contraindications to receiving this treatment long-term, in which case percutaneous left atrial appendage occlusion can be considered as a means of decreasing their embolic risk. Because the procedure requires transeptal puncture, the presence of devices for atrial septal defect closure can difficult the technique. We present the case of a patient with absolute contraindication to anticoagulation therapy given gastrointestinal bleeding, with history of percutaneous closure of interauricular communication, who was treated with percutaneous left atrial appendage occlusion as an alternative to oral anticoagulants.

7.
Ann Card Anaesth ; 2022 Mar; 25(1): 77-80
Article | IMSEAR | ID: sea-219181

ABSTRACT

Surgical exclusion of the left atrial appendage (LAA) for stroke prevention in atrial fibrillation is frequently incomplete and remains to be optimized. We present a man who did not tolerate anticoagulant and failed percutaneous occlusion. Intraoperative echocardiographic contrast was used to assist surgical exclusion. Follow?up showed a persistent occlusion.

8.
Chinese Journal of Geriatrics ; (12): 11-14, 2022.
Article in Chinese | WPRIM | ID: wpr-933024

ABSTRACT

Objective:To analyze the safety and efficacy of left atrial appendage closure(LAAC)with Watchman in patients ≥85 years with atrial fibrillation(AF).Methods:515 elderly patients with atrial fibrillation, including 73 patients aged 85 years or older(85~91), who had undergone Watchman LAAC at Zhoupu Hospital affiliated to Shanghai Health Medical College from August 2016 to December 2020, were retrospectively analyzed.Of those ≥85 years, 44(60.3%)with transesophageal echocardiography records were assigned to the elderly group.Fifty-three patients aged 60 to 65 were selected as the control group.Differences in baseline data, intraoperative conditions, antithrombotic treatment plans and 1-year follow-up prognosis were compared between the two groups.Results:Compared with the control group, there was no difference in AF types, history of ischemic stroke/transient ischaemic attack(all P>0.05), but there were higher incidences of coronary heart disease and renal insufficiency, more severe heart failure, higher CHA 2DS 2-VASC(6.0±1.5 vs.3.6±1.5), HAS-BLED(3.2±1.2 vs.2.3±1.3)scores( t values were 7.682 and 3.871, respectively, P<0.05), and a lower one-stop surgery rate(6 cases or 13.6% vs. 27 cases or 50.9%, χ2=10.517, P<0.05)in the advanced age group.There was no difference in the diameter of the Watchman device, rate of device replacement, compression percentage and residual flow between the two groups during the perioperative period.The incidences of device-related thrombosis were 4.5%(2/44)and 3.8%(2/53)for the advanced age group and the control group, respectively, but the difference was not statistically significant( P>0.05). During the 12-month follow-up, there were no cases of ischemic stroke or intracerebral hemorrhage.Three died of heart failure and 1 died of cancer. Conclusions:LAAC with Watchman is safe and effective for patients over 85 years with AF, but the decision on the procedure should be based on careful assessment of patients' cardiac and renal function and general health.

9.
Chinese Journal of Internal Medicine ; (12): 921-927, 2022.
Article in Chinese | WPRIM | ID: wpr-957663

ABSTRACT

Objective:To investigate the association between abnormal left atrial appendage function and thrombotic events in patients with non-valvular atrial fibrillation, and the independent risk factors affecting left atrial appendage function.Methods:Patients with non-valvular atrial fibrillation, who visited the Atrial Fibrillation Center of the First Affiliated Hospital of Xinjiang Medical University from June 1, 2019 to June 1, 2021, were selected. According to left atrial appendage flow velocity (LAAFV), they were divided into normal left atrial appendage function group (297 patients with LAAFV ≥ 40 cm/s) and abnormal left atrial appendage function group (85 patients with LAAFV<40 cm/s). Baseline data and transesophageal echocardiography images were collected from all the patients. The occurrence of thrombotic events was recorded. Univariate and multivariate unconditional logistic regression analyses were conducted to investigate the correlation between abnormal left atrial appendage function and the occurrence of thrombotic events.Results:There were significant differences in gender, type of atrial fibrillation, CHA 2DS 2-VASc score, anticoagulant therapy, total cholesterol, low-density lipoprotein cholesterol, international normalized ratio (INR), left atrial diameter, proportion of patients with right atrial enlargement, left ventricular ejection fraction, inner diameter, sum of inner diameter, depth, and sum of depth of all angles of the left atrial appendage, and incidence of thrombotic events between the two groups (all P<0.05). After adjusting for confounders, multivariate unconditional logistic regression analyses showed that abnormal left atrial appendage function was closely associated with thrombotic events (β=1.168 P=0.002), and left atrial diameter ( OR=1.084, 95% CI 1.019-1.153, P=0.011) and persistent atrial fibrillation ( OR=2.323, 95% CI 1.226-4.403, P=0.010) were independent risk factors affecting left atrial appendage function. Conclusions:Abnormal left atrial appendage function is closely associated with thrombosis. The left atrial diameter and persistent atrial fibrillation were independent risk factors affecting left atrial appendage function.

10.
Journal of Chinese Physician ; (12): 1298-1301, 2022.
Article in Chinese | WPRIM | ID: wpr-956297

ABSTRACT

Objective:To summarize the ultrasonophic features of left atrial appendage aneurysm, and to provide an important reference for the early and accurate diagnosis of left atrial appendage aneurysm.Methods:Patients with atrial appendage aneurysm have no obvious symptoms in the early stage, and there are many difficulties and challenges in diagnosis. This paper analyzed and summarized the diagnostic characteristics of a child with left atrial appendage aneurysm by combining the prenatal and postnatal ultrasonic imaging characteristics.Results:Echocardiography is the first choice for the diagnosis of left atrial appendage aneurysm. Some cases can make precise diagnosis prenatally.Conclusions:Echocardiography is the preferred imaging examination method for evaluating left atrial appendage aneurysm. Multimodal imaging technology can identify and diagnose left atrial appendage aneurysm early and accurately, and provide important basis for clinical diagnosis and treatment plan.

11.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 560-564, 2022.
Article in Chinese | WPRIM | ID: wpr-924685

ABSTRACT

@#Objective    To summarize the experience and efficacy of "one-stop" left atrial appendage clipping (LAAC) combined with transcatheter aortic valve replacement (TAVR) for patients with atrial fibrillation (AF) and aortic valve disease. Methods     From April 2018 to March 2021, 16 patients with AF and severe aortic valve disease underwent "one-stop" LAAC and TAVR in our department. All patients had long-standing persistent AF. There were 10 males and 6 females with an average age of 77.2±6.2 years. CHA2DS2-VASc score was 4.4±0.8 points, and HAS-BLED score was 3.5±0.7 points. Results    All patients successfully underwent "one-stop" LAAC combined with TAVR. There was no death during perioperative and follow-up periods. The length of the left atrial appendage base measured during the operation was 37.8±3.5 mm. The types of atrial appendage clip were 35 mm (n=3), 40 mm (n=8) and 45 mm (n=5). The time required for clipping the left atrial appendage (from skin cutting to skin suturing) was 25.7±3.8 min. There was no stroke or bleeding of important organs during the perioperative period. The average hospital stay was 6.8±2.0 d. The follow-up time was 19.6±10.1 months, during which there was no patient of cerebral hemorrhage or cerebral infarction. During the administration of warfarin, 2 patients had subcutaneous ecchymosis and 1 patient had gingival bleeding. Conclusion    "One-stop" LAAC combined with TAVR can be safely and effectively used to treat AF and aortic valve disease patients with high risk of thromboembolism and anticoagulant bleeding. The early and middle-term curative effect is satisfactory.

12.
Japanese Journal of Cardiovascular Surgery ; : 31-34, 2022.
Article in Japanese | WPRIM | ID: wpr-924533

ABSTRACT

The transcatheter left atrial appendage occluding device, WATCHMAN, can be used to prevent thromboembolism in patients with nonvalvular atrial fibrillation who are at high risk of bleeding during anticoagulation. We report an emergent surgical case of cardiac tamponade due to the left atrial appendage perforation with the WATCHMAN device implantation. An 83-year-old woman with recurrent paroxysmal atrial fibrillation (CHA2DS2-VASc score 4, HAS-BLED score 3) after catheter ablation was scheduled for the WATCHMAN device implantation. During implantation, the patient developed cardiac tamponade and underwent emergent surgery with cardiopulmonary bypass for active bleeding despite pericardial drainage. The bleeding was caused by the left atrial appendage perforation, and suture exclusion of the left atrial appendage was performed.

13.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 330-334, 2022.
Article in Chinese | WPRIM | ID: wpr-923382

ABSTRACT

@#Objective    To investigate the short-term efficacy and safety of thoracoscopy-assisted epicardial radiofrequency ablation for atrial fibrillation (AF) and/or left atrial appendage exclusion (LAAE). Methods    The clinical data of 12 patients with solitary AF admitted to Beijing Tiantan Hospital from November 2018 to August 2020 were retrospectively analyzed, including 7 males and 5 females, with an average age of 65.2±5.3 years. Of them, 2 had paroxysmal AF, 1 had persistent AF and 9 had permanent AF. Results    No patient died during hospitalization, 5 patients underwent radiofrequency ablation for AF and LAAE, and 6 received LAAE alone. The operation time was 293±70 min in radiofrequency ablation for AF+LAAE patients and 71±14 min in LAAE patients. Two patients restored sinus rhythm, two restored after electric cardioversion, and one remained AF in AF+LAAE patients. Postoperatively, 1 patient had pleural effusion and 1 had subcutaneous emphysema. No stroke was observed. Conclusion    Thoracoscopy-assisted radiofrequency ablation for AF and/or LAAE reduce the risk of procedure, and provide alternative approach to treat AF-associated diseases. However, large sample size studies using prospective cohort designs are required to corroborate the present findings.

14.
Chinese Journal of Emergency Medicine ; (12): 908-914, 2022.
Article in Chinese | WPRIM | ID: wpr-954518

ABSTRACT

Objective:To investigate the relationship of delayed cardiac tamponade (CT) after left atrial appendage closure (LAAC) in atrial fibrillation (AF) patients and implanted occluders and adjacent anatomical structures.Methods:This study was a retrospective study. Thirteen AF patients with LAAC complicated with delayed CT and with concurrent emergency pericardiocentesis drainage in Zhoupu Hospital, Shanghai University of Medicine & Health Sciences from August 2016 to June 2021 were selected. The follow-up time was (16±12) months. The clinical data of these patients were retrospectively analyzed, including the relationship between the left atrial appendage and pulmonary artery, vein anatomy by left atrium computed tomography angiography (CTA) before and after LAAC.Results:Thirteen patients with delayed CT were treated by pericardiocentesis and drainage after LAAC and aged (72.1±8.3) years, and 7 patients were male, Six patients received cryoablation simultaneously. The classification types of left atrial appendage included cauliflower and chicken wing types were 8 and 5 respectively. The seal plate diameter of the lobe-and-disc devices was (29.5±2.8)mm; 10 patients had cardiac CTA reviewed. The occluder was attached to pulmonary artery in 8 patients, attached to left superior pulmonary vein only in one patient, and attached to pulmonary artery and left superior pulmonary vein in one patient. The prognosis was good except one patient who died 2 days after LAAC.Conclusions:Delayed CT after LACC is closely related to the location of left atrial appendage adjacent to pulmonary artery and left superior pulmonary vein, and is related to larger occluder and anchor hook.

15.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 1492-1502, 2022.
Article in Chinese | WPRIM | ID: wpr-953547

ABSTRACT

@#Objective     To systematically evaluate the safety, efficacy, and economics of intracardiac echocardiography (ICE) versus transesophageal echocardiography (TEE) in left atrial appendage occlusion (LAAO). Methods     PubMed, EMbase, The Cochrane Library, CBM, CNKI, VIP and WanFang Database were systematically  searched to collect relevant studies on comparing ICE and TEE-guided LAAO from inception to June 15th, 2022. Two reviewers independently screened the literatures, extracted the data, and assessed the risk of bias of the included studies. Meta-analyses were performed using RevMan 5.3 and R 4.0.3. Retrospective cohort studies were excluded for sensitivity analysis. Subgroup analyses were performed based on the types of occluder and ICE catheter. Results     A total of 14 studies with 6 599 patients were included. Meta-analyses showed no statistical differences in technical success rate, overall complications, device embolization, peri-device leakage, device-related thrombus, stroke, vascular complications, bleeding, operation time, fluoroscopy time, or contrast agent volume between the ICE and TEE-guided LAAO. The total in-room time (MD=–33.47 min, 95%CI –41.20 to –25.73, P<0.000 01) and radiation dosage (MD=–170.20 mGy, 95%CI –309.79 to –30.62, P=0.02) were lower in the ICE group than those in the TEE group, whereas the incidence of pericardial effusion/tamponade was higher than the TEE group (RR=1.57, 95%CI 1.01 to 2.45, P=0.048). Except for pericardial effusion/tamponade, subgroup analyses and sensitivity analysis showed similar results. The analysis based on the cost data from the United States showed comparable or even lower total costs for ICE versus TEE, but comparative domestic cost studies were lacking. Conclusion     Current evidence suggests that ICE-guided LAAO can reduce radiation dosage and total in-room time, and there is no statistical difference in the overall complication rate between the two groups. Owing to the limitations of sample size and quality of the included studies, the conclusion still needs to be verified by large sample size and high-quality randomized controlled trials.

16.
J. Card. Arrhythm. (Impr.) ; 34(3): 128-134, Dec., 2021.
Article in English | LILACS | ID: biblio-1359640

ABSTRACT

Percutaneous procedures through femoral access in patients with inferior vena cava (IVC) filter may be at risk of complications. We evaluated the feasibility and safety of left atrial appendage closure (LAAC) through femoral access in patients previously implanted with IVC filter. We described the WatchmanTM device implantation in two patients with formal contraindication for oral anticoagulation. First patient had a GreenfieldTM filter and the second one an OpteaseTM filter, and in this patient an attempt to withdrawal the filter immediately before the LAAC procedure failed. A femoral approach was performed in both patients using a 14 Fr sheath. Before crossing IVC filters, venographies did not detect any thrombus. All steps of IVC filter crossing were performed under fluoroscopic guidance. No immediate or intrahospital complications related to the procedure occurred. Herein, we presented two cases of successful LAAC closure with Watchman device in patients with two different kinds of IVC filters.


Subject(s)
Atrial Fibrillation , Vena Cava Filters , Heart Atria
17.
Arch. cardiol. Méx ; 91(1): 42-49, ene.-mar. 2021. tab, graf
Article in Spanish | LILACS | ID: biblio-1152859

ABSTRACT

Resumen Objetivo: Analizar la utilidad clínica y la viabilidad de la tomografía cardíaca multidetector (TCMD) en la valoración de pacientes con fibrilación auricular (FA). Material y métodos: Estudio prospectivo de casos y controles en 84 sujetos (54 con FA y 30 controles). La morfología de la orejuela izquierda (OI) se clasificó en cactus, ala de pollo, manga de viento y coliflor. La presencia de trombo en la OI, el antecedente de accidente cerebrovascular y la escala CHA2DS2-VASc se compararon con parámetros obtenidos por TCMD. Resultados: La fracción de expulsión de la aurícula izquierda (FEAI) y la fracción de expulsión de la orejuela izquierda (FEOI) fueron más bajas en los individuos con FA (p < 0.001). El volumen indexado de la aurícula izquierda (VIAI) fue mayor en los pacientes con FA (p < 0.001). Se observó una correlación inversa entre la FEAI y el VIAI (r = -0.38, p < 0.001). La morfología tipo coliflor fue la más frecuente en enfermos con FA, mientras que la de tipo cactus predominó en los controles. La de tipo coliflor fue la más relacionada con presencia de trombos (p < 0.01), así como una calificación CHA2DS2-VASc alta. La velocidad de flujo fue menor en los pacientes con FA (p < 0.001). Conclusión: La TCMD es un método novedoso y no invasivo para una valoración integral en la FA. Los resultados de este estudio podrían mejorar la precisión, la utilidad clínica y el análisis de estratificación del riesgo en la FA. Los autores proponen incluir este nuevo método en la valoración integral del riesgo tromboembólico en pacientes con FA.


Abstract Objective: To analyze the clinical utility and feasibility of the multidetector cardiac tomography (MDCT) in multi-parametric imaging assessment in atrial fibrillation (AF) patients. Material and methods: Prospective case-control study in 84 subjects (54 AF subjects and 30 healthy subjects). Left atrial appendage (LAA) morphology was classified as: cactus, chicken wing, wind sock, cauliflower. Intra-cardiac thrombus, stroke history and CHA2DS2-VASC scale were compared to cardiac MDCT atrial imaging assessment. Results: Left atrial ejection fraction (LAEF) and LAA ejection fraction (LAAEF) were lower in AF subjects (p < 0.001), left atrial volume index (LAVI) was higher in AF subjects (p < 0.001). An inverse correlation between LAEF and LAVI was found (r = −0.38, p < 0.001). Cauliflower LAA morphology frequency was higher in AF subjects, whereas cactus LAA morphology frequency was higher in controls. Cauliflower LAA morphology was associated with thrombus presence (p < 0.01) as well as a higher CHA2DS2-VASc score. Flow velocity were lower in AF subject compared to controls (p < 0.001). Conclusion: MDCT is a novel, non-invasive, worldwide available method for an integral assessment in AF. Our results could improve precision, clinical utility and risk stratification analysis in AF. Our proposal is to include this new method into the global cardiovascular and thrombotic risk assessment in AF patients.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Atrial Fibrillation/diagnostic imaging , Cardiac Imaging Techniques , Multidetector Computed Tomography , Case-Control Studies , Prospective Studies
18.
Chinese Journal of Internal Medicine ; (12): 822-826, 2021.
Article in Chinese | WPRIM | ID: wpr-911445

ABSTRACT

To evaluate the efficacy and safety of left atrial appendage occlusion (LAAO) in patients with atrial fibrillation (AF) over 75 years. A total of 82 patients with AF who underwent LAAO successfully in Beijing Anzhen Hospital from March 2014 to March 2019 were divided into two groups according to age: the elderly group (aged>75 years) and the young group (aged ≤75 years). Risk of perioperative complications and incidence of ischemic stroke and major bleeding during follow-up were retrospectively analyzed. The results showed that there were no significant differences in procedure-related ischemic stroke(0 vs.1.6%, P=0.768) and major bleeding (0 vs.1.6%, P=0.768) during perioperative period between the two groups. No complications as death or pericardial tamponade occurred in the two group. During a (25.9±15.9) months period of followed up, ischemic stroke event rate was 3.6/100 person-years in the elderly group and 4.9/100 person-years in the young group, respectively. Major bleeding event rate was 2.5/100 person-years in the elderly group and 0/100 person-years in the young group, respectively. Compared with the expected ones, the relative risk reduction (RRR) of stroke in the elderly group was more profound than that in the young group (32.0% vs. 25.0%), while the risk of major bleeding in the young group was significantly lower than that in the elderly group (RRR 100% vs. 56.9%). Therefore, LAAO might be suitable for stroke prevention in the elderly AF patients.

19.
Chinese Journal of Medical Instrumentation ; (6): 355-360, 2021.
Article in Chinese | WPRIM | ID: wpr-888623

ABSTRACT

At present, the standard left atrial appendage occlusion procedure mainly involves two-dimensional imaging methods such as X-ray fluoroscopy and transesophageal echocardiography to guide the operation, which will lead to underestimation of the three dimensional structure of the left atrial appendage and the surrounding tissue, thus adversely affects the surgery. To solve this problem, a surgery assist system for left atrial appendage occlusion based on preoperative cardiac CT images is developed. The proposed system realizes the left atrial appendage parameter measurement based on cardiac CT image, and realizes the calculation of optimal delivery sheath trajectory and three-dimensional simulation of the delivery sheath movement on the basis of a novel delivery sheath trajectory model. The system is expected to provide precise guidance for left atrial appendage occlusion, improve the success rate and safety of the operation, and at the same time help reduce the difficulty of learning the operation, and facilitate the promotion of left atrial appendage occlusion.


Subject(s)
Humans , Atrial Appendage/surgery , Atrial Fibrillation/surgery , Cardiac Catheterization , Echocardiography, Transesophageal , Tomography, X-Ray Computed , Treatment Outcome
20.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 1016-1020, 2021.
Article in Chinese | WPRIM | ID: wpr-886700

ABSTRACT

@#Left atrial appendage occlusion is a common procedure for patients with atrial fibrillation history when they underwent cardiac surgery. Before the LAAOS Ⅲ research results, this operation has been lacking strong evidence-based support. LAAOS Ⅲ is a prospective, double-blind, international multicenter, randomized blinded trial. According to the results of LAAOS Ⅲ, the left atrial appendage occlusion can reduce the risk of stroke and systemic embolism. This article will perform detailed interpretation of LAAOS Ⅲ research.

SELECTION OF CITATIONS
SEARCH DETAIL